Range of application: remote control of valves for switching tasks. |
|
Construction:
insulation class F, 3 thermo switch Operation mode: Short term operation S2 – 15 min. Protection class: IP 68 / EN 60529 Cutoff: 2 limit switch, 2 torque switch. Electrical equipment: flasher unit for running indication: mech. travel indicator, heating in switch compartment Temperature: - 40°C to + 80°C ambient temperature. | |||||||||||||||||||||||||||||||||
Fig. 1203
|
Special constructions: |
Typ | ØD | Ød ¹) | L ¹) | L₁ | H₁ | B | d₁ | d₂ | weight appr. kgs |
---|---|---|---|---|---|---|---|---|---|
SA 07.2-A ²) | 160 | 101 | 265 | 249 | 288 | 300 | 125 | 70 | 19 |
SA 07.6-A ²) | 160 | 101 | 265 | 249 | 288 | 300 | 125 | 70 | 21 |
SA 10.2-A ²) | 200 | 121 | 283 | 254 | 290 | 312 | 125 | 70 | 25 |
SA 14.2-A ²) | 315 | 153 | 389 | 336 | 316 | 375 | 175 | 100 | 48 |
dimensions in mm ¹) exact measure depending on motor used ²) Output drive according to ISO 5210 F 10 + F 14 (actuatorSA 14.2) – standard– also possible according to DIN 3210 form A (threaded bush) |