Range of application: remote control of valves for switching tasks. |
| Construction: Auma-norm rotary drives, with manual adjustment, with threaded bush form A, connectionEN ISO 5210 or DIN 3210 Output speeds: 4; 5,6; 8; 11; 16; 22; 32; 45; 63; 90 rpm. Standard-voltage: three-phase
Operation mode: intermittent operation S 4 – 25% ED protection class: IP 68 Cutoff: 2 limit switch, 2 torque switches. Electrical equipment: mechanical travel indicator, heating in switch compartment Temperature: - 40°C to + 60°C ambient temperature. | |||||||||||||||||||||||||
Fig. 1204
|
Special constructions: |
type | ØD | Ød ¹) | L ¹) | L₁ | H₁ | B | d₁ | d₂ | weight appr. kgs |
---|---|---|---|---|---|---|---|---|---|
SAR 07.2-A ²) | 160 | 105 | 265 | 249 | 288 | 300 | 125 | 70 | 20 |
SAR 07.6-A ²) | 160 | 105 | 265 | 249 | 288 | 300 | 125 | 70 | 21 |
SAR 10.2-A ²) | 200 | 125 | 283 | 254 | 290 | 312 | 125 | 70 | 25 |
SAR 14.2-A ²) | 315 | 153 | 389 | 336 | 316 | 375 | 175 | 100 | 48 |
dimensions in mm ¹) exact measure depending on motor used ²) Output drive according to ISO 5210 F 10 + F 14 (actuator SAR 14.2) – standard – also possible according to DIN 3210 form A (threaded bush) |